The Wiper Gold Wipe Test Counter
|
Price: Call JRT for Pricing
|
- Choose results in CPM, DPM, nCi, µCi, mCi, Bq, KBq or MBq
- User-programmable trigger levels
- Reverse decay a test run of samples automatically
- Q.C. hot samples – 300,000+ CPS with excellent linearity
- Exceeds NRC and state requirements
- Calibrate with Cs137, Na22 or Co57
- AutoSpect™ automatic DPM
- Sample volume correction
- View and analyze samples with a 4096 channel MCA
- Extremely flexible sample count times
- Decay calculator; decay a sample to the past or future
- Iterative count function, set it up and walk away
- Powerful, yet simple to use
The Wiper™ Gold is first and foremost an advanced, easy to use, wipe counter. The Wipe Library features storage for up to 30 unique wipe tests. Whether wiping outgoing packages, or checking a fume hood, there is room to configure a location to your needs. Configuration options include setting a location name, count time, background subtract, and trigger level.
Let’s face it, there is no one solution to fit all wipe test needs. That’s why the Wiper™ Gold allows you to choose your own Pass/Fail trigger levels and automatically calculates the MDA (minimal detectable activity.
Software – Simplicity, Re-defined
Load your wipe into the well and press the button. Your wipe is counted and automatically converted to DPM. If the wipe is above trigger, it is flagged and the contaminating isotope identified – that’s all there is to it.
LTIW100US
|
Wiper Gold™ Single Well Wipe Test Counter
Self contained complete with wipe testing with advanced features such as: isotope
identification, high count rate over 18M CPM (300,000 CPS), Sample volume correction,
Assay Library for up to 8 tests, forward and reverse decay, Autospect™ report DPM for
any isotope. Powerful MCA with PHA functionality, Iterative counting, long count time up
to 45 days.
|
LTIW101US
|
Wiper Gold™ LSV Single Well Wipe Test Counter
Self contained complete with wipe testing with advanced features such as: isotope
identification, high count rate over 18M CPM (300,000 CPS), Sample volume correction,
Assay Library for up to 8 tests, forward and reverse decay, Autospect™ report DPM for
any isotope, 0-2Mev range. Powerful MCA with PHA functionality, Iterative counting, long
count time up to 45 days. The HE contains a solid NaI(tl) crystal with a counting well that
can accommodate centrifugal vials 1.22” (31mm) in diameter and 3.6”(91.5mm) deep.
|
LTIW101US-LID
|
Optional Detector Shield Lid for Wiper Gold™ LSV allows for tubes up to 3.6” (91.5mm)
|
LTI028US
|
Optional Printer
|
LTI008
|
Replacement Well Liners, 5
|
|
|
|