Pro-RF AAPM 15 DSA Phantom


ection I and II: Step Wedge moduleSection III: Slot blockRegistration PlateBone SectionHigh Contrast Resolution SectionBlank InsertLinearity Insert Low Contrast Artery Insert150mg/ml Iodine Artery Insert300mg/ml Iodine Artery Insert
Price: Call JRT for Pricing
Item Number: 02-117



This Digital Subtraction Angiography (DSA) Phantom follows the recommendation in Report No. 15 by the AAPM (American Association of Physicists in Medicine) - Digital Radiology/Fluorography Task Group of the Diagnostic X-Ray Imaging Committee. Phantom is designer to evaluate digital functions of DSA systems and can be used to check: contrast range, resolution, linearity, uniformity, amplifier dynamic range, registration accuracy and subtraction effectiveness. Its modular construction allows to setup up the desired test configuration in a very easy and accurate manner.  Includes:

Section I and II Step Wedge module, 6 step wedges (each 25.4mm high) to test dynamic range. Can be folded into 203.2 x 203.2 x 76.5mm solid block
Section III Slot block with a place to fit other test modules. Outer size: 203.2 x 203.2 x 76.5mm. Slot size: 203.2 x 152.4 x 25.4mm
Registration Plate Made of aluminum with array of 3.18mm holes. Size: 203.2 x 203.2 x 1.5mm
Bone Section Three PTFE strips 25mm width and 5, 10 and 15mm in thickness. Size: 203.2 x 203.2 x 25.4mm
High Contrast Resolution Section Contains pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm). Thanks to dedicated recesses test pattern can be placed in different orientations. Size: 203.2 x 203.2 x 25.4mm
Blank Insert  When used with other models forms mask plate. Size: 203.2 x 152.4 x 25.4mm
Linearity Insert Contains 6 iodine areas (19mm diameter) having different iodine thickness and concentration: 0.5, 1.0, 2.0, 4.0, 10.0 and 20.0 mg/cm2. Size: 203.2 x 152.4 x 25.4mm
Low Contrast Artery Insert Contains 3 sets of analogue blood vessels (diameters 0.5, 1.0, 2,0 and 4.0mm), each vessels group includes different iodine concentrations: 2.5, 5.0 and 10.0 mg/cc. Size: 203.2 x 152.4 x 25.4mm
Iodine Artery Insert
150mg/ml , 3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctial and arterial aneurysm which sizes are 1/4, 1/2 and 3/4 of artery diameter. Size: 203.2 x 152.4 x 25.4mm
Iodine Artery Insert
300mg/ml , 3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctia and arterial aneurysm which sizes are 1/4, 1/2 and ¾ of artery diameter.  Size: 203.2 x 152.4 x 25.4mm
Carrying Case


Complies with AAPM Report No. 15 - Performance Evaluation and Quality Assurance in Digital Subtraction Angiography - Diagnostic X-Ray Imaging Committee/Digital Radiography/ Fluorography Task Group - May 1985 and IEC 61223-3-1. CE certified. Manual provides detailed guidelines for carrying out each test, results assessment and registration.