NEED HELP?
Call JRT at 800-221-0111
8 am to 5 pm EST
|
Pro-RF AAPM 15 DSA Phantom

 ection I and II: Step Wedge module Section III: Slot block Registration Plate Bone Section High Contrast Resolution Section Blank Insert Linearity Insert Low Contrast Artery Insert 150mg/ml Iodine Artery Insert 300mg/ml Iodine Artery Insert |
|
Price: Call JRT for Pricing
Item Number: 02-117
|
This Digital Subtraction Angiography (DSA) Phantom follows the recommendation in Report No. 15 by the AAPM (American Association of Physicists in Medicine) - Digital Radiology/Fluorography Task Group of the Diagnostic X-Ray Imaging Committee. Phantom is designer to evaluate digital functions of DSA systems and can be used to check: contrast range, resolution, linearity, uniformity, amplifier dynamic range, registration accuracy and subtraction effectiveness. Its modular construction allows to setup up the desired test configuration in a very easy and accurate manner. Includes:
| Section I and II
|
Step Wedge module, 6 step wedges (each 25.4mm high) to test dynamic range. Can be folded into 203.2 x 203.2 x 76.5mm solid block
|
|
| Section III
|
Slot block with a place to fit other test modules. Outer size: 203.2 x 203.2 x 76.5mm. Slot size: 203.2 x 152.4 x 25.4mm
|
|
| Registration Plate
|
Made of aluminum with array of 3.18mm holes. Size: 203.2 x 203.2 x 1.5mm
|
|
| Bone Section
|
Three PTFE strips 25mm width and 5, 10 and 15mm in thickness. Size: 203.2 x 203.2 x 25.4mm
|

|
| High Contrast Resolution Section
|
Contains pattern for line pair resolution evaluation (from 0.6 to 5.0 LP/mm). Thanks to dedicated recesses test pattern can be placed in different orientations. Size: 203.2 x 203.2 x 25.4mm
|

|
| Blank Insert
|
When used with other models forms mask plate. Size: 203.2 x 152.4 x 25.4mm
|

|
| Linearity Insert
|
Contains 6 iodine areas (19mm diameter) having different iodine thickness and concentration: 0.5, 1.0, 2.0, 4.0, 10.0 and 20.0 mg/cm2. Size: 203.2 x 152.4 x 25.4mm
|

|
| Low Contrast Artery Insert
|
Contains 3 sets of analogue blood vessels (diameters 0.5, 1.0, 2,0 and 4.0mm), each vessels group includes different iodine concentrations: 2.5, 5.0 and 10.0 mg/cc. Size: 203.2 x 152.4 x 25.4mm
|

|
Iodine Artery Insert
|
150mg/ml , 3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctial and arterial aneurysm which sizes are 1/4, 1/2 and 3/4 of artery diameter. Size: 203.2 x 152.4 x 25.4mm
|

|
Iodine Artery Insert
|
300mg/ml , 3 sets of analogue blood arteries (thickness 1.0, 2.0, 4.0 mm) each includes arteriarctia and arterial aneurysm which sizes are 1/4, 1/2 and ¾ of artery diameter. Size: 203.2 x 152.4 x 25.4mm
|

|
| Carrying Case
|
|
|
Complies with AAPM Report No. 15 - Performance Evaluation and Quality Assurance in Digital Subtraction Angiography - Diagnostic X-Ray Imaging Committee/Digital Radiography/ Fluorography Task Group - May 1985 and IEC 61223-3-1. CE certified. Manual provides detailed guidelines for carrying out each test, results assessment and registration.
|
|
|