NEED HELP?
Call JRT at 800-221-0111
8 am to 5 pm EST
|
Pro-NM Performance Phantom
|
Price: Call JRT for Pricing
|
The Pro-NM Performance Phantom is used for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
The Pro-NM Performance Phantom is compatible with Diagnomatic QC Solutions,a
web-based service that makes it possible to easily organize and manage
the quality control of any number of diagnostic imaging systems. The
platform supports a DICOM protocol that allows seamless integration with
your hospital IT system making data transfer safe and easy. The Pro-NM SPECT BASIC Kit is a versatile set of phantoms and software for carrying out constancy
tests of radiography and fluoroscopy units. Thanks to the Diagnomatic
subscription, all tests can be quickly and effortlessly automatically analyzed online and with the desktop app.
Technical data (can be modified to customer specifications):
- Main cylinder:
- inside cylinder diameter: 206mm
- inside cylinder height: 186mm
- cylinder wall thickness: 7mm
- Cold rods insert:
- rod diameters: 4.8, 6.4, 7.9, 9.5, 11.1 and 12.7 mm
- height of rods: 88mm
- Cold spheres:
- solid sphere diameters: 9.5, 12.7, 15.9, 19.1, 25.4 and 31.8mm
- height of the center of the spheres from the base plate: 127mm
- Optional PET Lid with cylindrical samples:
- refillable thin-walled cylinders, diameters: 8, 12, 16 and 25mm
- water filled cylinder diameter: 25mm
- air filled cylinder diameter: 25mm
- PTFE solid cylinder diameter: 25mm
- cylinder height: 38mm
- Optional Heavy duty carrying case
- Optional hollow spheres set (08-104)
- Optional heavy duty carrying case (08-110)
- Complies with NEMA Standards Publication (NU 1-2001) Performance Measurements of Scintillation Cameras, AAPM Report No. 9 - Computer Aided Scintillation Camera Acceptance Testing, AAPM Report No. 22 - Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control, ACR–SNM (Res. 5 – 2011) technical standard for diagnostic procedures using radiopharmaceuticals
- CE certified
- Manual provides detailed guidelines for carrying out each test, results assessment and registration
08-101
|
Pro-NM Performance
|
08-103
|
Pro-NM Performance with PET Lid
|
08-104
|
Pro-NM Performance - hollow sphere set
|
08-114
|
Pro-NM Performance - micro-hollow sphere set
|
08-110
|
Case for Pro-NM Performance
|
|
|
|