Item Number: 01-303
|
The Pro-Dent CT MINI phantom is a versatile quality control tool of dental Cone-Beam CT, Dental Volume Tomography (DVT) and other 3D imaging devices with small FOVs (Field Of View).
The phantom consists of a main PMMA cylinder that houses modules with different test objects. It allows performing most important imaging quality test such as:
- image geometry
- slice geometry
- pixel (matrix) size
- artifacts, noise
- homogeneity
- linearity
- contrast
- high-contrast resolution
- low-contrast resolution (contrast sensitivity)
The Pro-Dent CT MINI is compatible with Diagnomatic QC Solutions,a
web-based service that makes it possible to easily organize and manage
the quality control of any number of diagnostic imaging systems. The
platform supports a DICOM protocol that allows seamless integration with
your hospital IT system making data transfer safe and easy. The Pro-Dent 3D BASIC Kit i a versatile set of phantoms and software for carrying out constancy tests of CBCT, DVT and other 3D imaging devices. Thanks to the
Diagnomatic
subscription, all tests can be quickly and effortlessly automatically
analyzed online and with the desktop app.
Complies with IEC 61223-3-4 and IEC 61223-3-5. CE certified. Manual
provides detailed guidelines for carrying out each test, results
assessment and registration.
Main Cylinder
|
- Contains markings for easy positioning in the dental unit and geometric distortion section
- An array of 2.0 mm diameter, 3.0 mm long holes uniformly pitched at 10.0 mm intervals
- Diameter: 110 mm, Length: 130 mm
- Made of PMMA (1.19 g/cm3)
|

|
Noise /Uniformity module
|
20 mm thick
|

|
Linearity Module
|
Contains 15 mm rods made of PTFE, poliamid, PE-300, air and water emulating epoxy embedded PMMA - pixel intensity / HU values samples
|

|
High Contrast Resolution Module
|
- Contains 7 objects for resolution evaluation: 10, 11, 12, 13, 14, 15, 16 LP/cm
- 0.3 mm bead for Modular Transfer Function (MTF) calculation
|

|
Low Contrast Module
|
Contains rods of a different diameters: 2, 3, 4, 6, 8, 10, 12 mm, filled with a substance whose density is 3% different from the body of the module
|

|
Slice Geometry Module
|
- 4 air rods, 3 mm in diameter, placed in vertices of the 30 mm square
- 2 aluminum wire ramps
|

|
Accessories
|
- Test stand with spirit level for accurate placing of the phantom in the test position
- Convenient, portable case for storing and transporting the phantom
|
|
|