NEED HELP?
Call JRT at 800-221-0111
8 am to 5 pm EST
|
Pro-CT mk II
|
|
Price: Call JRT for Pricing
Item Number: 04-410
|
The Pro-CT mk II phantom can be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines. This phantom consists of several test modules placed inside a cylindrical container that can be mounted either directly on a holder of the CT table or on an adjustable stand. It allows accurate alignment for measurements on and off the table. Markings on the phantom and leveling aids provide further facilitation of the positioning process.
The Phantom can be used to do the following tests:
- Geometric distortion
- CT number (HU) measurement
- Noise / Uniformity
- Artifacts
- MTF
- SSP, LSF, PSF
- CNR
- Spatial resolution
- Spatial resolution in Z dimension
- Contrast resolution
- Low contrast resolution
- Slice profile
- Alignment
- Linearity
- Beam width
Technical data (can be modified to customer specifications):
- Main module contains PMMA section with an array of holes 2mm in diameter, 4mm deep, placed at 10mm intervals
- Outside diameter 230mm
- Length 250mm
- Optional external beam hardening rings:
- 380mm outside diameter (04-317)
- 350mm outside diameter (04-318)
- 300 – 380mm outside oval diameter (04-319)
- 450 – 550mm outside oval diameter (04-320)
- Positioning stand for on and off table measurements
- Complies with IEC 61223-3-5, IEC 61223-2-6, AAPM guidelines, and ACR guidelines. CE certified.
- Manual provides detailed guidelines for carrying out each test, results assessment and registration.
- Carrying case
The Pro-CT mk II phantom is compatible with Diagnomatic QC Solutions,a web-based service that makes it possible to easily organize and manage the quality control of any number of diagnostic imaging systems. The platform supports a DICOM protocol that allows seamless integration with your hospital IT system making data transfer safe and easy. The Pro-CT BASIC Kit and the Pro-CT PRO Kit are versatile sets of phantoms and software for carrying out constancy tests of radiography and fluoroscopy units. Thanks to the Diagnomatic subscription, all tests can be quickly and effortlessly automatically analyzed online and with the desktop app.
Low contrast module
|
- Diameter: 200 mm
- Thickness 30 mm
- Made of PMMA
- Contains three groups of low-contrast objects: in each group, there are rods of the same density, 20 mm in height and with a diameter ranging from 1 to 15 mm. Contrast difference between groups and surrounding material is 0.3, 0.6 and 1%
- Optional subslice targets having a nominal 1.0% contrast and z-axis lengths of 3, 5, and 7 mm. For each of these lengths, there are objects of 3, 5, 7 and 9 mm in diameter (04-411)
|

|
Sensitometric / contrast module
|
- Diameter: 200 mm
- Thickness: 30 mm
- Contains 9 sensitometric samples shaped like rods (ø25 mm): PTFE, LDPE, POM-C, ABS, PA-6, PET, air, plastic water equivalent and PMMA – modules body
|

|
Geometry module
|
- Diameter: 200 mm
- Thickness 30 mm
- Contains two pairs of aluminium wire ramps whose slope angle tangent is equal to 0.5
- Middles of ramps intersect on the same plane allowing very precise evaluation of the slice location
- Contains four ø5 mm rods and four ø3 mm rods from the air in the vertices of the regular octagon close to the outer perimeter of the phantom for evaluating symmetry and circular geometry
- Optional nine spheres to evaluate the scanner’s imaging of subslice spherical volumes, diameters: 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 and 9.0 mm (04-413)
|

|
|
Spatial / high contrast module
|
- Diameter: 200 mm
- Thickness: 30 mm
- Contains 13 concentrically placed high contrast elements for spatial resolution evaluation from 1 to 13 LP/cm
- Two tungsten carbide beads ø0.18 mm and ø0.28 mm for MTF and SSP calculation
- Linear Spread Function (LSF) PTFE / PMMA interface
- Point Spread Function (PSF) - 0.25 mm stainless steel wire in air
- 0ptional, additional concentrically placed high contrast elements for spatial resolution evaluation from 14 to 30 LP/cm (04-414)
|

|
Water fillable module
|
- Diameter: 200 mm
- Thickness 35 mm
- Can be filled with water
|

|
Pro-water module
|
- Diameter: 200 mm
- Thickness 35 mm
- Mimics true water within 1% accuracy
|

|
Optional electron density module (04-416)
|
- Diameter: 200 mm
- Thickness: 30 mm
- Module made of PMMA
- Contains samples of 10 different rod-shaped materials (25mm diameter) with the known physical and electron density corresponding to the following tissues: lungs (inhale), lungs (exhale), breasts (50.50), dense bone, bone marrow, liver, muscles, adipose tissue; additionally, a sample with water and a optional titanium rod
|

|
04-410
|
Pro-CT mk II
|
04-411
|
Pro-CT mk II - optional subslice targets in low contrast module
|
04-413
|
Pro-CT mk II - optional spheres in geometry module
|
04-414
|
Pro-CT mk II - optional wider range of patterns in resolution module - up to 30 LP/cm
|
04-416
|
Pro-CT mk II - optional electron density module
|
04-417
|
Pro-CT mk II - optional external beam hardening ring 380mm outside diameter
|
04-418
|
Pro-CT mk II - optional external beam hardening ring 350mm outside diameter
|
04-419
|
Pro-CT mk II - optional external beam hardening ring 300 – 380mm outside oval diameter
|
04-420
|
Pro-CT mk II - optional external beam hardening ring 350 – 550mm outside oval diameter
|
| 04-421
|
Pro-CT mk II - optional upgrade to module made of Pro-Water water-equivalent
|
| 04-422
|
Pro-CT mk II - titanium rod core insert for optional electron density module
|
|
Price: Call JRT for Pricing
The Pro-CT Basic Kit is a versatile set of phantoms and software for carrying out constancy tests of computed tomography units.
|
Price: Call JRT for Pricing
The Pro-CT Pro Kit is a versatile set of phantoms and software for carrying out constancy and acceptance tests of computed tomography units.
| |
|
|