IMRT Head
and Neck Phantom
|
|
The Model 002HN IMRT Head and Neck Phantom properly represents human head and neck anatomy in shape, proportion and structure as well as density. This enables thorough analysis of both the treatment planning and delivery systems.
|
|
|
| |
 |
IMRT Head & Torso Freepoint Phantom
|
|
With the IMRT Head & Torso Freepoint Phantom, choose any point dose location within a circular area with diameter of 11.2 cm by simply adjusting the two rotating cylinders. Lung and bone equivalent rods can be positioned at any location within the circular area for assessment of heterogeneity correction. Remove the center cylinder from the phantom body to simulate head and neck set-ups.
|
|
|
| |
 |
IMRT Thorax Phantom
|
|
The IMRT Thorax Phantom for Film and Ion chamber Dosimetry is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems while providing a simple yet reliable method for verification of individual patient plans and delivery. The phantom is elliptical in shape and properly represents an average human torso in proportion, density and two-dimensional structure.
|
|
|
| |
 |
IMRT Pelvic
3D Phantom
|
|
The IMRT Pelvic 3D Phantom is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and verification of individual patient plans and delivery. The phantom properly represents human pelvic anatomy in shape, proportion and structure as well as density.
|
|
|
| |
 |
IMRT Homogeneous Phantom
|
|
The IMRT Homogeneous Phantom for Film and Ion chamber Dosimetry is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems while providing a simple yet reliable method for verification of individual patient plans and delivery. The phantom is homogeneous and elliptical in shape, and properly represents human anatomy in size and proportion.
|
|
|
| |
 |
IMRT Dose Verification Phantom
|
|
The anthropomorphic design of the IMRT Dose Verification Phantom mimics human anatomy which assists in set up and treatment for patient dose verification. It is ideal for prostate and head and neck regions, as well as for commissioning respiratory gated protocols
|
|
|
| |
 |
ACE IMRT Phantom
|
|
The ACE IMRT Phantom is designed to accurately validate IMRT treatment plans. The ACE IMRT Phantom can be used to obtain axial and coronal views of treatments plans. It includes edge slabs with a radius to minimize scatter from CT scanning.
|
|
|
| |
 |
Cube 20 Phantom
|
|
The Cube 20 Phantom was designed for routine QA in RT and IMRT applications where ease of use and quick set-up are important. The Cube 20 phantom is manufactured from Plastic Water® DT which faithfully mimics water within 1% from 50 keV to 25 MeV.
|
|
|
| |
 |
Dynamic Platform
|
|
Programmable motion for any phantom - the Dynamic Platform provides an economical, user-friendly solution for the complex tasks associated with tumor motion and patient positioning in radiation therapy.
|
|
|
| |
 |
Respiratory Gating Platform
|
|
The unique Respiratory Gating Platform simulates breathing providing the means to create a comprehensive program for commissioning, training, quality assurance and dose verification of gated IMRT treatments.
|
|
|
| |
|